Principle
Ultrasonic waves enter the component. Signals resulting from propagation and interaction with the material provide information about internal areas. A suitable configuration can also determine thickness.
Applications
- Volumetric examination of suitable welds.
- Searching for internal discontinuities in metallic components.
- Localized thickness measurements on pipework and walls.
- Monitoring defined measurement points within a maintenance programme.
Equipment
- Welded assemblies
- Metallic pipework and walls
- Components with suitable geometry and material structure
Discontinuities sought
- Internal discontinuities producing a detectable response
- Some planar discontinuities, depending on orientation
- Thickness variations at the measured locations
Technical limitations
- Material, structure and geometry determine feasibility.
- Scanning access and surface condition may limit coverage.
- Individual readings do not constitute a complete corrosion map.
Standards and acceptance criteria
ISO 17640:2018 addresses manual ultrasonic weld testing, particularly ferritic welds within its scope; ISO 11666:2018 provides acceptance levels. Thickness determination is a separate objective addressed by ISO 16809:2025. The technique and contractual edition are agreed before inspection.
An indicative workflow
Establish the objective
Specify weld testing, discontinuity detection or thickness measurement. Provide material, dimensions and drawings.
Define coverage
Agree examination areas or measurement grids, access and assessment criteria.
Perform the examination
Verify settings suitable for the application and examine the agreed areas while maintaining location traceability.
Report the results
Present indications or measured values, achieved coverage and limitations affecting interpretation.
Documentation
- UT examination report or thickness record, as specified.
- Identification of examined areas and measurement points.
- Value tables, indication locations and available records included in the quotation.
Frequently asked questions
Does a thickness reading certify fitness for service?
No. The value must be assessed against the equipment documentation, allowable limits and defined responsibilities.
Which ultrasonic technique will be used?
The technique is specified after reviewing the requirement and confirming available resources. Specialist techniques are not included by default.
What should be included with the request?
Grade, nominal thickness, diameter where relevant, weld drawing or measurement points, coating, access and required criteria.